Hollywood and Pompano Beach Seawall Requirements
Hollywood and Pompano Beach seawall requirements both start at 5 feet NAVD88, and both cities rewrote them in February 2022. After that they split. Hollywood kept the county's 4 foot option and Pompano Beach didn't.
Get your wall checked by a licensed contractor
Hollywood
Hollywood's rule is Sec. 150.30, passed as Ordinance O-2022-01 on February 2, 2022. It follows the county closely.
§ 150.30 RESILIENCY STANDARDS FOR TIDAL FLOOD BARRIERS.
(D) Minimum elevations for tidal flood barriers.
(1) All new or substantially repaired or substantially rehabilitated banks, berms, green-grey infrastructure, seawalls, seawall caps, upland stem walls, or other similar infrastructure shall be designed and constructed to perform as tidal flood barriers. Tidal flood barriers shall have a minimum elevation of five feet NAVD88. Applications for new or substantially repaired or substantially rehabilitated tidal flood barriers submitted prior to January 1, 2035, may be permitted at a minimum elevation of four feet NAVD88, if designed and constructed to accommodate a minimum elevation of five feet NAVD88 by January 1, 2050.
(2) All property owners must maintain a tidal flood barrier in good repair. A tidal flood barrier is presumed to be in disrepair if it allows tidal surface waters to flow unimpeded through or over the barrier and onto adjacent property or public right-of-way. Failure to maintain a tidal flood barrier in good repair shall be a citable offense. The owner of the tidal flood barrier shall demonstrate progress towards repairing the cited defect within 60 days after receiving a citation and shall complete repairs within 365 days after receipt of the citation. If the required repair or rehabilitation meets the substantial repair or substantial rehabilitation threshold, no later than 365 days after receipt of the citation, the property owner shall design, obtain permits, cause to be constructed, and obtain final inspection approval of seawall improvements that meet the minimum elevation and design requirements.
Hollywood Code Sec. 150.30 (Ord. O-2022-01), AmLegal. Source, pulled Nov. 21, 2026.
What counts as substantial in Hollywood? On the cost side, the City Engineer decides.
§ 150.30 RESILIENCY STANDARDS FOR TIDAL FLOOD BARRIERS.
SUBSTANTIAL REPAIR or SUBSTANTIAL REHABILITATION. A single and complete project which is the total project proposed or accomplished by one owner/developer, partnership, or other association of owners/developers, and where major shoreline improvement triggers either of the following:
(a) Any modification to the shoreline or a shoreline structure along more than 50% of the length of the property's shoreline; or
(b) Any modification, alteration, or installation of an appurtenant structure (such as a mooring structure) that exceeds 50% of the cost of a new tidal flood barrier along the property’s shoreline as determined by the City Engineer.
Hollywood Code Sec. 150.30 (Ord. O-2022-01), AmLegal. Source, pulled Nov. 21, 2026.
Selling soon? This is the wording the contract needs.
§ 150.30 RESILIENCY STANDARDS FOR TIDAL FLOOD BARRIERS.
(E) Required disclosure in contracts for sale of real estate. In any contract for the sale of real estate located in tidally influenced areas within the City of Hollywood, executed after the effective date of this subchapter, the seller shall include in the contract or a rider to the contract the following disclosure in not less that fourteen point, capitalized, bold-face type:
THIS REAL ESTATE IS LOCATED IN A TIDALLY INFLUENCED AREA. THE OWNER MAY BE REQUIRED BY BROWARD COUNTY OR HOLLYWOOD CODE OF ORDINANCES TO MEET MINIMUM TIDAL FLOOD BARRIER ELEVATION STANDARDS DURING CONSTRUCTION OR SUBSTANTIAL REPAIR OR SUBSTANTIAL REHABILITATION OF SEAWALLS, BANKS, BERMS, AND SIMILAR INFRASTRUCTURE OR WHEN REQUIRED TO ABATE NUISANCE FLOODING.
(Ord. O-2022-01, passed 2-2-22)
Hollywood Code Sec. 150.30 (Ord. O-2022-01), AmLegal. Source, pulled Nov. 21, 2026.
Pompano Beach
Pompano Beach keeps its rule in Sec. 151.05, last amended by Ordinance 2022-28 on February 8, 2022. There's a ceiling, and no 2035 or 2050 date anywhere in it.
§ 151.05 TIDAL FLOOD BARRIERS.
(A) All new or substantial repair or substantial rehabilitation of banks, berms, green-grey infrastructure, seawalls, seawall caps, upland stem walls, or other similar infrastructure shall be designed and constructed to perform as tidal flood barriers. Tidal flood barriers shall have a minimum elevation of five feet NAVD88 and shall not exceed an elevation of five feet ten inches NAVD88. Persons desiring to construct or repair a tidal flood barrier or rip-rap shall obtain all required permits and furnish a plan to the City Engineer for approval, which are prepared by an engineer licensed in the State of Florida, showing elevations, and proposed and adjacent seawalls referenced to North American Vertical Datum of 1988 (NAVD 88).
(F) All tidal flood barriers below five feet NAVD88 undergoing substantial repair or substantial rehabilitation shall be brought to the minimum height of five feet NAVD88 and shall be constructed along the property's entire shoreline.
(G) All tidal flood barriers below five feet NAVD88 shall be brought to the minimum height of five feet NAVD88 when modifications, alterations, or installation of appurtenant structures (such as mooring structures) exceed 50% of the cost of a tidal flood barrier along the property’s entire shoreline.
Pompano Beach Code Sec. 151.05 (Am. Ord. 2022-28), AmLegal. Source, pulled Nov. 21, 2026.
So a Pompano wall getting substantial work has a 10 inch window, 5 feet to 5 feet 10. The plans have to come from a Florida-licensed engineer.
Moving the wall out into the canal is limited too.
§ 151.05 TIDAL FLOOD BARRIERS.
(M) The maximum width of a seawall cap cannot exceed 36 inches seaward from the wet face of the existing tidal flood barrier or rip-rap.
(N) Unless approved by the City Engineer, the wet-face of a reconstructed tidal flood barrier or rip-rap shall not exceed 12 inches from the wet-face of the existing tidal flood barrier or rip-rap. A request to exceed 12 inches must include; a signed and sealed detailed drawing of the existing tidal flood barrier or rip-rap, a signed and sealed statement by a licensed Florida engineer that structural damage will occur to the adjacent properties if a new tidal flood barrier or rip-rap is installed within 12 inches of the existing wet face of the existing tidal flood barrier or rip-rap and all necessary approvals, permits and/or exemptions from the Broward County Environmental Protection and Growth Management Department, Florida Department of Environmental Protection or South Florida Water Management District, United States Army Corps of Engineers, and other governmental agencies as applicable, unless subject to the exceptions set forth in F.S. § 403.813.
Pompano Beach Code Sec. 151.05 (Am. Ord. 2022-28), AmLegal. Source, pulled Nov. 21, 2026.
Next door to each other, different paperwork
Both cities give a cited owner 60 days to show progress and 365 to finish. What counts as substantial under the county model is on the Broward seawall ordinance page.